List of Laboratory Services

 

 

 

 AFFYMETRIX GeneChip: Hybridization & Data Analysis:    ● Standard Microarray Suite sorting analysis  -  Regon's original sorting approach

     proven to generate most-reliable data                   [click ? here for more]

 

 

  AFFYMETRIX GeneChip Data Analysis

      ● Customized data analysis output exploring GeneSpring and other software packages     [Contact: data_analysis@regon-inc.com]

    ● Customized data analysis representation solutions and high-quality design graphics preparation. [data_analysis@regon-inc.com]

 

 

  Custom Microarray Preparation

Customized Nucleic-acid and Protein microarray preparation using any size of nucleic acids or proteins on Regon's proprietary coated polished or thermal-oxide quartz-glass, reflection silicone wafers or reflection plastic slides. Regon's microarray substrates offer the following:

      ● Amazing 100-times higher probe surface-attachment compared to any other products - immediately upon surface contact!

      ● Dual-array preparation - both nucleic acids and proteins attached on one microarray - great for biodefense applications!

      ● Additional up to 10-times signal increase due to mirror-like reflective back-surfacing!

      ● Enhanced probe amount attachment on thermal-oxide derivatized slides and on porous-glass slides. 

     e  See our related products for more INFO:  click ?  M110-114 series Microarray Slides - glass, silicon, quartz

 

 

  Custom cDNA Libraries Preparation

Regon Molecular Systems has developed the NewGeneration RT-priming Technology™, an ultra-enhanced Reverse-transcription initiation and cDNA synthesis platform technology (Argonne National Laboratory Invention Report ANL-IN-94-074; Intellectual property of Regon Molecular Systems, Inc.) for highly improved enhanced and efficient detection, measurement, cloning, amplification and analysis of biologically expressed sequences - all features build-in the synthesized cDNA. No cloning is necessary for in vivo library amplification (linear and/or exponential), screening or expression - all can be performed in vitro.

    The NewGeneration RT-priming Technology™ is dedicated for large-scale genome analysis and extended search for new genes understudied via current priming technologies such as polyA-minus gene transcripts.

 

 

 Customized Research Plans/Strategies Development - Including Step-By-Step Protocols

      ● Development complete customized research strategies, including detailed protocols, suppliers etc.   [click ? here for more]

     ● Custom advisory-, evaluation-, demonstration-, tutorial- and consultation services.

 

 

►  Large Spectrum of General Laboratory Services

e See our related SERVICES below      [click ? here for ordering form as:  MS WORD -or- ACROBAT  version]

Laser-Capture Microdissection (LMD) - Training Session-1 (introductory).

LMD Practical Training - Training Session-2.  

LMD Service Manipulation by trained pathologist with image-capture.

LMD by Service Manipulation by technical investigator.

LMD Consultation.

Each CapSure.

Slides Preparation for Leica DM LMD.

Taking of pictures on LCM-camera with CD-backup.

Slide Preparation by cutting-of frozen sections.

Slide Preparation by cutting-of paraffin sections 5-10 mm.

Slide Preparation by cutting-of sections 20-50 mm.

Staining H&E (frozen).

H&E (paraffin).

Slide Sections Reviewing by pathologist with written expertise.

Laboratory Equipment Usage  (Smart-cycler, cryostat, microtome, staining set etc).

RNA or DNA mini-extraction by micro-column method (1-4 samples).

RNA or DNA mini-extraction by micro-column method (5-15 samples).

RNA or DNA mini-extraction by micro-column method (16 or more samples).

RNA mini-extraction by micro-column and cDNA synthesis (1-4 samples).

RNA mini-extraction by micro-column and cDNA synthesis (5-10 samples).

RNA mini-extraction by micro-column and cDNA synthesis (11 samples).

RNA or Protein mini-extraction from LMD (1-4 samples).

RNA or Protein mini-extraction from LMD (5-10 samples).

RNA or Protein mini-extraction from LMD (11 samples).

RNA mini-extraction from LMD and cDNA synthesis (Enhanced Technology*).

RNA mini-extraction from LMD and cDNA synthesis (Enhanced Technology*).

RNA mini-extraction from LMD and cDNA synthesis (Enhanced Technology*).

RNA mini-extraction from LMD and cDNA synthesis via Linear-Amplification Enhanced Technology** [RNA®cDNA®cRNA1®cDNA®bio-cRNA2] (1-4 samples).

RNA mini-extraction from LMD and cDNA synthesis via Linear-Amplification Enhanced Technology** [RNA®cDNA®cRNA1®cDNA®bio-cRNA2] (5-10 samples).

RNA mini-extraction from LMD and cDNA synthesis via Linear-Amplification Enhanced Technology** [RNA®cDNA®cRNA1®cDNA®bio-cRNA2] (11 samples).

Complete Affymetrix® GeneChip® Service with Standard total-RNA amount (1-15 mg).

Complete Affymetrix® GeneChip®Service*** with starting total-RNA amount of 0.1-1.0 mg; via Enhanced Technology*; no extra-step linear-amplification included.

Complete Affymetrix® GeneChip® Service*** with starting RNA (total- or mRNA) amount of 0.01-1.0 mg; via MegaYield Technology with single extra linear-amplification step.

Complete Affymetrix® GeneChip® Service*** with starting RNA (total- or mRNA) amount of  0.01ng – 0.1 mg; via click ? NewGeneration Priming

 Technology double-step extra linear-amplification. [AVAILABLE from July 2006]

 


 

All products sold by Regon Molecular Systems, Inc. are intended for research use only unless otherwise indicated. This product is not intended for diagnostic or drug purposes. The product has not been qualified or found safe and effective for any human or animal diagnostic or therapeutic application.  Uses for other than the intended use may be a violation of applicable laws.

Warranty: Regon Molecular Systems, Inc. is committed to providing the highest quality reagents at competitive prices. Regon Molecular Systems, Inc. warrants that the product will mediate or exceed these specifications when used (under normal conditions) in your laboratory.  We will promptly replace the product free of charge if the product does not conform to these specifications. Our obligation and your sole remedy are limited to such replacement in the event that the product proves to be defective.  No otter warranties are expressed or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.  Regon Molecular Systems, Inc. shall have no liability for any direct, indirect, consequential or incidental damages arising from the use, results of use, or inability to use its products. Shipping temperature may differ from storage temperature. This will not alter the performance of the product.

 

This bulletin is for your guidance and is based upon information and tests believed to be reliable. Regon Molecular Systems, Inc makes no guarantee of the accuracy or completeness of the data and shall not be liable for any damages thereto. The data are offered solely for your consideration, investigation, and verification. These suggestions should not be confused with either  state municipal or insurance requirements, or with national safety codes and constitute no warranty. Any use of these data and information must be determined byte user to be in accordance with, applicable federal, state, and local regulations.

 

_____________________________________________________________________________________________________________________________________

The material on this site is protected under the copyright laws of the United States of America and international conventions, and is the exclusive property of REGON

Molecular Systems, Inc. All rights reserved. 2003. REGON Molecular Systems, Inc.  Touhy Dental Center, 7238 W. Touhy Street  ·  Chicago, IL 60630 ·  Tech Support: 773-589-0151

·  e-mail: techsupport@regon-inc.com  ·  www.regon-inc.com

 

Search This Site

Shipping Info

BioInformation Links

BioDatabase Links

Useful Technical Info